Project Server 2016 – Force In/Out not available

One of the issues we ran into with the latest version of project server (2016) is that the client was not able to Force In/Out projects in the portfolio analysis.

Our Expertise

Join our mailing list

When the user tried to select Force In or Force Out no option was available.

Now, there was something special with this site collection. The PWA was created in the root of the web application and the URL was something like http: //abc .

If the PWA was created somewhere else (e.g. http: //abc/sites/PWA) then everything worked fine.

After migrating the site collection to a different location (e.g. http: //abc/Sites/PWA2) everything worked fine.

The conclusion is that we should avoid creating PWAs in the root of the web application, at least for the moment. If you ran into the above issue the solution is to migrate the content to a different location, other then the root of the web application.